Capacitive Level Sensors CG/CGS/CG65 (Phase Detection)
?Level Switches ?Capacitive Level Instruments
關鍵詞:
所屬分類:
產品附件:
咨詢熱線:
詳情介紹
MODEL:CG-2N
Main application
Virtually any liquids, solids and bulk solids
Main feature
-
Easy programming by push buttons
-
Multifunctional with microcomputer
-
First level switch to have status indicating LCD
-
Improved buildup prevention performance
-
Extremely reliable
Principle of operation
The basic oscillator circuit is of the parallel resonance circuit with L (coil) and C (capacitance between the electrodes).
The oscillation frequency (f) of this circuit is : f = 1/2 π √LC.
The frequency without material around the sensor (f1) is: f1 = 1/2 π √LC, where C is the capacitance without material around the sensor (zero point).
With material around the sensor, the capacitance increases (C+ΔC), and the frequency (f2) is: f2 = 1/2 π √L(C+ΔC), where C+ΔC is the capacitance with material around the sensor (span point).
The sensor detects the frequency change from f1 to f2, and actuates the relay. The frequency range is divided into 8 segments (between zero and span), and the set and reset points assigned on a desired segment, which means high limit, low limit and hysteresis can be programmed.
Set range is divided into 8 segments, and ON/OFF points are set for the segments. Hysteresis is also programmable.